Product Details

Heat Pump VRF

6 Ton to 30 Ton

• All DC Inverter Technology
• 30 Ton Max Capacity
• Non-polar CAN Technology
• Modules Rotation Operating
• Anticorrosive Golden Fins
• Emergency Operation Function
• Compact Design
• Wider Application Location
• High Efficiency
• Energy-saving
• Intelligent Debugging

Submittals

Specifications T-VRF Heat Pump

Models Outdoor Unit TVRF-OC72KHP/220V TVRF-OC96KHP/220V TVRF-OC120KHP/220V
Capacity Ton 6 8 10
Capacity Cooling Btu/h 69,000 92,000 114,000
Heating Btu/h 77,000 103,000 129,000
Power Supply V/Ph/Hz 208/230V~3~60Hz 208/230V~3~60Hz 208/230V~3~60Hz
EER – IEER (Ducted/Non-Ducted) 13.7/13.7 – 21.5/28.1 13.2/13.2 – 20/20.26 12.4/12.4 – 23.3/25.2
High COP 47°F (Ducted/Non-Ducted) 4.22 / 4.22 4.15 / 4.15 3.95 / 3.95
MOCP A 45 70 100
Rated Current A 30 45 74
Maximum drive IDU NO. unit 13 16 19
Refrigerant Charge Volume Oz 229.3 398.7 416.3
Airflow CFM 6,079 8,239 8,239
Sound Pressure Level dB(A) 60 61 63
Piping connection Liquid inch Φ3/8 Φ3/8 Φ1/2
Gas inch Φ3/4 Φ7/8 Φ1-1/8
Oil balance inch Φ3/8 Φ3/8 Φ3/8
Dimensions WxHxD Outline inch 36-5/8 x 63-1/5 x 30-1/8 52-3/4 x 63-1/4 x 30-1/8 52-3/4 x 63-1/4 x 30-1/8
Net/Gross Weight Lbs 496/518 662/694 794/827
Loading Quantity 40’HQ set 24 16 16

 

Specifications of Outdoor Unit Combinations

Model Power Supply Capacity Dimensions (WxDxH) Airflow ESP
Cooling Heating
V/Ph/Hz Btu/h Btu/h In. CFM in.W.G
TVRF-OC72 KHP/220V 208/230V~3~60Hz 69,000 77,000 36-3/5*30-1/8*63-1/5 6,080 0.33
TVRF-OC96 KHP/220V 208/230V~3~60Hz 92,000 103,000 52-3/4*30-1/8*63-1/5 8,230 0.33
TVRF-OC120 KHP/220V 208/230V~3~60Hz 114,000 129,000 52-3/4*30-1/8*63-1/5 8,230 0.33
TVRF-OC144 KHP/220V 208/230V~3~60Hz 138,000 154,000 (36-3/5*30-1/8*63-1/5) ×2 6,080 x 2 0.33
TVRF-OC168 KHP/220V 208/230V~3~60Hz 161,000 180,000 (36-3/5*30-1/8*63-1/5)+ (52-3/4*30-1/8*63-1/5) 6,080 + 8,230 0.33
TVRF-OC192 KHP/220V 208/230V~3~60Hz 184,000 206,000 (52-3/4*30-1/8*63-1/5) x2 8,230 x 2 0.33
TVRF-OC216 KHP/220V 208/230V~3~60Hz 206,000 232,000 (52-3/4*30-1/8*63-1/5) x2 8,230 x 2 0.33
TVRF-OC240 KHP/220V 208/230V~3~60Hz 228,000 258,000 (52-3/4*30-1/8*63-1/5) x2 8,230 x 2 0.33
TVRF-OC264 KHP/220V 208/230V~3~60Hz 253,000 283,000 (36-3/5*30-1/8*63-1/5)+ (52-3/4*30-1/8*63-1/5) x2 6,080 + 8,230x 2 0.33
TVRF-OC288 KHP/220V 208/230V~3~60Hz 276,000 309,000 (52-3/4*30-1/8*63-1/5) x3 8,230 x 3 0.33
TVRF-OC312 KHP/220V 208/230V~3~60Hz 298,000 335,000 (52-3/4*30-1/8*63-1/5) x3 8,230 x 3 0.33
TVRF-OC336 KHP/220V 208/230V~3~60Hz 320,000 361,000 (52-3/4*30-1/8*63-1/5) x3 8,230 x 3 0.33
TVRF-OC360 KHP/220V 208/230V~3~60Hz 342,000 387,000 (52-3/4*30-1/8*63-1/5) x3 8,230 x 3 0.33